Innovative Technologies.

Torontech

Spectroscopy and Spectrometry Instruments - Fourier Transform Infrared Spectroscopy - FTIR

Fourier Transform Infrared Spectroscopy - FTIR

Fourier Transform Infrared Spectroscopy (FTIR) is a technique used to obtain an infrared spectrum of absorption, emission, photoconductivity or Raman scattering of a solid, liquid or gas. An FTIR spectrometer simultaneously collects high spectral resolution data over a wide spectral range. This confers a significant advantage over a dispersive spectrometer which measures intensity over a narrow range of wavelengths at a time.

How Can We Help You?

Contact our sales team for a quotation.

Powerful MainFTOS Suite software comes with specialized IR libraries, real-time instrument status diagnosis, modular platform design, FDA CFR 21 Part 11 Compliance, and auto software updating. It is also compatible with all windows versions.
High sensitivity optical system ensuring long term stability, without the need of dynamic alignment which needs extra complicated electronic circuits.
High stability modular partition design greatly improves the mechanical stability and long term working stability of the instrument.
Intelligent multi-sealed moisture-proof design for preventing influences of high temperature, high humidity and chemical corrosions to the optical system in many ways.
Innovated integration electronic system ensuring high quality real-time data collection and high-speed transmission.
The electronic system is designed to meet CE certification and electromagnetic compatibility requirements, minimizing electromagnetic radiation in design and technology.
High intensity, long lifetime IR source module, with the highest energy distributed in fingerprint region, adopts a reflex sphere design to obtain even and stable IR radiation.
The sampling compartment reserving accessory mounting holes on the base plate, is designed for various accessories such as Defused/Specular Reflection, ATR, Liquid cell, GaS cell, and IR microscope etc.

Interferometer
Cube-corner Michelson interferometer
Beam splitter
Multilayer Gecoated KBr
Detector
Room temperature DLATGS module (standard)
Temperature stabilized, high sensitivity DLATGS module (optional)
IR Source
High intensity, long lifetime, air-cooled IR source
Wavenumber Range
7800cm-1~350cm-1
Resolution
0.85 cm-1
Signal to noise ratio
Better than 20,000:1 (RMS value, at 2100cm-1 ~ 2000cm-1 or 2100cm-1 ~ 2200cm-1, resolution: 4cm-1, detector: DLATGS, 1 minute data collection)
Wavenumber Accuracy
±0.01 cm-1
Scanning Speed
Microprocessor control, different scanning speed selectable.
Software
MainFTOS Suite software workstation, compatible to all version Windows OS
Various specialized functional software modules (optional)
Communication
Ethernet interface (standard)
WIFI wireless communication (optional)
Data Output
Standard data format, report generation and output
Status Diagnosis
Power on self-check, real-time temperature and humidity monitoring and reminders
Certification
FDA 21 CFR Part11 compliance,IQ/OQ/PQ
Environment Conditions
Temperature: 10℃~30℃, humidity: less than 70%
Dimensions & Weight
520 x 435 x 255mm, 24kg
Accessories
Transmission sample holder (Standard)
Optional accessories such as gas cell, liquid cell, Defused/Specular Reflection, single/multi reflection ATR, etc.
Quote Form
Please Contact us for pricing, check availability, or ask for additional information about our Fourier Transform Infrared Spectroscopy – FTIR
Scroll to Top