Innovative Technologies.

Torontech

Concrete & Cement Testing Equipment - Automatic Vicat Needle Apparatus - 6 Stations

Automatic Vicat Needle Apparatus - 6 Stations

Save time without sacrificing precision and accuracy! The Automatic Vicat Needle Apparatus - 6 Stations is used for testing materials that have no real melting points. The main principle is that it measures the temperature at which a flat ended needle is able to penetrate the sample. This is known as the softening point of the material. 

Without the input of an operator, this machine saves time without sacrificing precision and accuracy. The Automatic Vicat Needle Apparatus - 6 Stations is designed to automatically apply the force to the sample while it records the depth of the needle. Just press a button and wait for the results! This unit allows for further time saving by performing the same test 6 times simultaneously. The Automatic Vicat Needle Apparatus - 6 Stations is a PC-controlled unit equipped with software running on the Windows operating system. Tests are perform according to ASTM C191 standards Without the input of an operator, this machine saves time without sacrificing precision and accuracy. The Automatic Vicat Needle Apparatus - 6 Stations is designed to automatically apply the force to the sample while it records the depth of the needle. Just press a button and wait for the results! This unit allows for further time saving by performing the same test 6 times simultaneously. The Automatic Vicat Needle Apparatus - 6 Stations is a PC-controlled unit equipped with software running on the Windows operating system. Tests are perform according to ASTM C191 standards:

  • 1.0 mm diameter needle
  • 300 g dropping weight
  • 6 conical rings with 40 mm height
  • Bottom diameter 70 ± 3 mm
  • Top diameter 60 ± 3 mm
  • Able to run tests under 90% humidity
  • The Automatic Vicat Needle Apparatus - 6 Stations consist of:

  • Test panel with 6 measuring rings
  • Standard software with programmable test sequences
  • Data recording and test protocol/graphics available
  • Water bath temperature controlled (heater/cooler to maintain water temperature @ 21 °C)
  • Six spare cleaning brushes
  • Six spare vicat needs (1.00 mm diameter)
  • Dimensions: 700 x 555 x 600 mm
  • Weight: approx. 52 kg
  • How Can We Help You?

    Contact our sales team for a quotation.

    Please Contact us for pricing, check availability, or ask for additional information about our Automatic Vicat Needle Apparatus – 6 Stations
    Scroll to Top