Innovative Technologies.

Torontech

Environmental Test Chamber - 2-Zone Thermal Shock Test Chamber

2-Zone Thermal Shock Test Chamber

2-Zone Thermal Shock Test Chamber series hot cold thermal shock test chamber is available in small capacity and large capacity to meet different testing requirements. The specimen automatic transferred from cold chamber to hot chamber by basket. The basket slides vertically and smoothly through rails, to make the specimen is exposed to the two chambers.

Thermal shock test chamber has upgraded to touch-screen controller with Ethernet, you are easy to operate over network.

Key Feature

  • Smooth sample elevator transfer between cold chamber to hot chambers
  • Temperature recovery time less than 15 minutes
  • Programmable color LCD touch screen controller
  • Mechanical compression refrigeration system
  • Casters, shelf, and cable port are standard
  • Lamp inside of chamber
  • Ethernet and USB (option)
  • Large viewing window
  • Adjustable and removable sample shelves
  • Safety protection system
  • CE mark, ISO17025 calibration
  • Refrigerating system

  • Refrigerant: environment friendly R404 refrigerant
  • Closed-type and low-noise rotor compressor
  • Refrigeration mode: machinery compression single-step refrigeration (air-cooled condenser) and machinery compression dual cascade system refrigeration
  • R404 refrigerant: environmental protection refrigerants
  • Control system:

  • Touch-type temperature and humidity programmable controller
  • Operating interface: LCD display
  • Temperature and humidity controller: touch-type LCD controller
  • Setting mode: touching type
  • Running mode: setting-up running and programmed running
  • Program: 100 groups in 100 segments
  • Resolution: temperature: ± 0.1 ℃; humidity: ± 1%RH
  • Input: platinum thermal resistance
  • Control mode: PID control
  • Communication function: LAN network interface
  • Additional function: alarm and display function, power-off protection function, upper limit temperature alarm function, timing function (auto start and auto stop), self-diagnosis function, curve record and display function, paperless record, USB data export, tele-monitoring and so on.
  • It can execute 100 STEP X 10 PATTEM mode.
  • Each section can be grouped and executed in crossing way.
  • The execution time for each section can be set up between 0-999H plus 59min.
  • For setting up for each group, it can circulate within 1-999 in part or entirely for option.
  • In execution, it can select group circle picture or section execution picture and can know the remaining time for execution.
  • It has power-off function. After power recovery, it can complete the remained test.
  • It can select single-section control or multi-section programmable control.
  • The screen has backlight time control function and it can adjust the backlight brightness.
  • For executing single-section control, it can change the execution value at will. The memory-type multi-function control has automatic control output functions, such as heating heater and humidifying heater for electromechanical solenoid valve for different groups of refrigerating compressors and so on.
  • Safety Device

  • Power supplyAC220±10%V 50±0.5Hz single-phase double-wire + protective grounding wire/ AC380±10%V 50±0.5Hz three-phase four-wire+ protective grounding wire (other voltage option with extra cost for transformer)
  • Standard Accessories

    1 cable hole (Φ50mm), with plug; 2 shelves

    Structures

    ENVIRONMENTAL TEST CHAMBER
    1.Workroom
    2.Sample Shelf
    3.Cable Hole
    The internal material is 304 stainless steel, mirror surface, rust-proof to high and low temperature and moisture corrosion; Nice ruggedness and long life. The specimen automatic transferred from cold chamber to hot chamber by basket. The basket slides vertically and smoothly through rails, to make the specimen is exposed to the two chambers.
    SUS304 stainless steel punching sample shelf 2pcs; Standard load of 15KGS for each layer of sample shelf; The height of the shelf is adjustable and can be removed directly to facilitate the various sizes of test samples. Conducive to the air circulation.
    A standard test hole, located at top of the work room, is provided with a sleeve inside to prevent moisture from entering the insulation layer. Equipped with flange. The standard inner hole diameter is 50mm. Soft silicone plug seal; Metal enclosure closed, beautiful designed.

    4.Viewing Window
    5.Controller
    6.Castor
    Double layer insulating glass 8cm thick, made of tempered glass. The conductive film is located on the interior glass to prevent window frosting, built-in LED light for the work room lighting, can clearly observe samples. The light control button is located below the controller.
    PID programmable color touch screen controller, network connection computer. It can edit 100 programs 100 segments. LIB also can pre-set program into the controller based on user testing requirements. The set system language is English for standard.
    Install 4 castors for ease moving, and with brakes function. Caster height adjustable.

    7.Insulation
    10cm thick polyurethane foam and insulation cotton; Better insulation performance, degradation resistance, environmental protection, noise reduction.

    Core Function
    Cooling System

    After the liquid refrigerant absorbs the heat of the cooled object in the evaporator, it is vaporized into low-temperature and low-pressure steam, sucked by the compressor, compressed into high-pressure high-temperature steam, discharged into the condenser, and radiated to the cooling medium in the condenser, condensed into a high-pressure liquid, throttling through a throttle valve into a low-pressure low-temperature refrigerant, and again entering the evaporator to absorb heat and vaporize, to achieve the purpose of cycle refrigeration. In this way, the refrigerant completes a refrigeration cycle through four basic processes of evaporation, compression, condensation, and throttling in the system.
    Air Circulation

    The centrifugal fan is installed at the rear of the chamber body, and the air is uniformly distributed through the air outlet. Air circulation adopts air outlet at top and air return at bottom, and the wind speed and pressure are in compliance with the test standard, and the temperature is stabilized at the moment of switching. The high-quality centrifugal fan is used to strongly supply air circulation, making the temperature distribution in the test area uniform
    Controller System

    The PID controller as the main control unit to command, operate, detect and redistribute the various components of the equipment to achieve maximum effective use. The temperature control adopts P.I.D. S.S.R. system synchronous coordinated control, which can improve the stability and life of the control components and interface. Screen display function: LCD display, which can display test conditions (including temperature section, cycle number, running time and remaining time, etc.).
    Temperature Sensor

    PT-100 Class A sensor, real-time accurate detection and display of temperature changes at 0.001 degrees.
    Wiring System

    Voltage 380V 50Hz 3 phase.

    L1, L2, L3, PE, N, grounding protection.

    Standard 2m long cable

    Protection System
    Over Temperature Protection
    Over Current Protection
    Refrigerant High Pressure Protection
    Earth Leakage Protection
    Phase Sequence Protection
    Option
    Sample Shelf
    Quantity can be increased
    Special sample shelf can be customized
    Power Cords
    2.5m
    3m
    Test Hole
    Diameter 100mm
    Diameter 125mm
    Shape and size can be customized
    Capacitive Temperature Sensor
    VAISALA
    ROTRONIC
    Observation Window
    Size can be customized
    Inner glass door
    Hand-in ports
    Reverse Osmosis Unit
    Controller
    WiFi connection
    Mobile APP control
    Multi-language controller interface: Russian, French, Polish, Romanian, German
    Model
    TTTS-162
    TTTS-340
    TTTS-500
    TTTS-1000
    Interior Volume
    22L
    72L
    211L
    505L
    Loading Capacity
    20kg
    30kg
    50kg
    60kg
    Pre-heat Room
    Upper limit Temperature
    +220°C
    Heating Time
    Ambient ~ +200°C, within 30 minutes
    Pre-cool Room
    Lower limit Temperature
    -75°C
    Cooling time
    Ambient ~ -70°C, within 30 minutes
    Test room
    High Temperature Exposure Range
    Ambient +20 ~ +200°C
    Low temperature Exposure Range
    -65 ~ -5°C
    Temperature Fluctuation
    ≤±0.5 °C
    Temperature Deviation
    ≤±3 °C
    Cooling
    Cooling System
    Mechanical compression refrigeration system
    Refrigerating Unit
    French TECUMSEH compressor
    Refrigerant
    R404A, R23
    Heating Element
    Nichrome heater
    Controller
    Programmable color LCD touch screen controller
    Ethernet connection, PC Link
    Temperature Sensor
    PTR Platinum Resistance PT100Ω/MV A-class, accuracy 0.001°C
    View Window Size(mm)
    130x150
    180x230
    250x280
    300x300
    Air Circulation
    Centrifugal wind fan
    Safety Device
    Over-temperature Protection; Over-current Protection; Refrigerant High-pressure Protection; Earth leakage Protection
    Exterior Material
    Steel Plate with protective coating
    Interior Material
    SUS304 stainless steel
    Thermal Insulation
    Polyurethane foam and insulation cotton
    Observation Window
    Interior lighting, double-layer thermo stability silicone rubber sealing
    Standard Configuration
    1 Cable hole (Φ 50,) with plug; 2 shelves
    Power Supply
    380V 50HZ (60hz with optional transformer)
    Maximum Noise
    65 dBA
    Environmental Conditional
    5°C ~ +35°C ≤85% RH
    Internal Dimensions (mm)
    300x300x250
    450x450x360
    650x650x500
    850x850x700
    Overall Dimension (mm)
    1560x870x1545
    1710x1020x1845
    1910x1220x2265
    2110x1420x2665
    Quote Form

    How Can We Help You?

    Contact our sales team for a quotation.

    Please Contact us for pricing, check availability, or ask for additional information about our 2-Zone Thermal Shock Test Chamber
    Scroll to Top